CyberSecBulletin
CVE-2025-4008Exploited in the wildNVD status: Analyzed

Smartbedded Meteobridge Command Injection

CVE-2025-4008 is a high-severity improper neutralization of special elements used in a command vulnerability in MeteoBridge from Smartbedded, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. Affected MeteoBridge versions: 6.1 and earlier. The record does not name a fixed version, so check the vendor advisory. CISA added it to the Known Exploited Vulnerabilities catalogue on October 2, 2025, which means attacks have been observed in the wild.

Patch now

Attackers are already exploiting this vulnerability, according to CISA.

What to do

  1. Update Meteobridge VM to 6.2 or a later version.
  2. Update Meteobridge Firmware to 6.2 or a later version.
  3. CISA's required action: Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
  4. Read the advisory on forum.meteohub.de for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
SmartbeddedMeteoBridge6.1 and earlierNot stated
SmartbeddedMeteobridge VMbefore 6.26.2
SmartbeddedMeteobridge Firmwarebefore 6.26.2

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
AdjacentThe attacker must be on the same local network segment.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.08.7HighCNA (onekey.com)
CVSS 3.18.8HighNVD

Official description

The Meteobridge web interface let meteobridge administrator manage their weather station data collection and administer their meteobridge system through a web application written in CGI shell scripts and C. This web interface exposes an endpoint that is vulnerable to command injection. Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: active, automatable: yes, technical impact: total).
  3. Added to CISA's Known Exploited Vulnerabilities catalogue.
  4. Deadline for US federal agencies to remediate, set by CISA.
  5. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.