Industrial Edge Cloud Device (IECD): Authorization Bypass Through User-Controlled Key
CVE-2025-40805 is a critical-severity authorization bypass through user-controlled key vulnerability in Industrial Edge Cloud Device (IECD) from Siemens, with a CVSS 3.1 base score of 10.0 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version V1.24.2 as the first without the flaw, so updating Industrial Edge Cloud Device (IECD) to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.65% chance of exploitation within 30 days, higher than 52% of scored CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Update Industrial Edge Cloud Device (IECD) to V1.24.2 or a later version.
- Update Industrial Edge Device Kit - arm64 V1.24 to V1.24.2 or a later version.
- Update Industrial Edge Device Kit - arm64 V1.25 to V1.25.1 or a later version.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- ChangedThe attack can reach beyond the vulnerable component into other systems.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H. Scored by CNA (siemens.com).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 10.0 | Critical | CNA (siemens.com) |
| CVSS 3.1 | 10.0 | Critical | CNA (siemens.com) |
Official description
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Authorization Bypass Through User-Controlled Key
The system's authorization functionality does not prevent one user from gaining access to another user's data or record by modifying the key value identifying the data.
How developers prevent this class of flaw
- For each and every data access, ensure that the user has sufficient privilege to access the record that is being requested.
- Make sure that the key that is used in the lookup of a specific user's record is not controllable externally by the user or that any tampering can be detected.
- Use encryption in order to make it more difficult to guess other legitimate values of the key or associate a digital signature with the key so that the server can verify that there has been no tampering.
More Authorization Bypass Through User-Controlled Key vulnerabilities (CWE-639)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Recent Authorization Bypass Through User-Controlled Key vulnerabilities
- 8.2 High severity
- 8.1 High severity
- 8.8 High severity
- 7.5 High severity
- 7.5 High severity
- 8.2 High severity
Spotted an error? Tell us.