Simcenter Femap: Use of Uninitialized Resource
CVE-2025-40829 is a high-severity use of uninitialized resource vulnerability in Simcenter Femap from Siemens, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. The record lists version V2512 as the first without the flaw, so updating Simcenter Femap to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.21% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Simcenter Femap to V2512 or a later version.
- Read the advisory on cert-portal.siemens.com for workarounds and exact fixed builds.
- Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Siemens | Simcenter Femap | before V2512 | V2512 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- RequiredA user must take an action such as opening a file or link.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (siemens.com).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 7.3 | High | CNA (siemens.com) |
| CVSS 3.1 | 7.8 | High | CNA (siemens.com) |
Official description
A vulnerability has been identified in Simcenter Femap (All versions < V2512). The affected applications contains an uninitialized memory vulnerability while parsing specially crafted SLDPRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-27146)
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Use of Uninitialized Resource
The product uses or accesses a resource that has not been initialized.
How developers prevent this class of flaw
- Explicitly initialize the resource before use. If this is performed through an API function or standard procedure, follow all required steps.
- Pay close attention to complex conditionals that affect initialization, since some branches might not perform the initialization.
- Avoid race conditions (CWE-362) during initialization routines.
More Use of Uninitialized Resource vulnerabilities (CWE-908)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in Simcenter Femap
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.3 High severity
Recent Use of Uninitialized Resource vulnerabilities
- 8.7 High severity
- 8.7 High severity
- 7.5 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
Spotted an error? Tell us.