CyberSecBulletin
CVE-2025-41648NVD status: Deferred

IndustrialPI 4 with IndustrialPI webstatus: Incorrect Type Conversion or Cast

CVE-2025-41648 is a critical-severity incorrect type conversion or cast vulnerability in IndustrialPI 4 with IndustrialPI webstatus from Pilz, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 2.4.6 as the first without the flaw, so updating IndustrialPI 4 with IndustrialPI webstatus to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.83% chance of exploitation within 30 days, higher than 58% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update IndustrialPI 4 with IndustrialPI webstatus to 2.4.6 or a later version.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
PilzIndustrialPI 4 with IndustrialPI webstatusbefore 2.4.62.4.6

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (cert.vde.com).

Official description

An unauthenticated remote attacker can bypass the login to the web application of the affected devices making it possible to access and change all available settings of the IndustrialPI.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Incorrect Type Conversion or Cast

The product does not correctly convert an object, resource, or structure from one type to a different type.

More Incorrect Type Conversion or Cast vulnerabilities (CWE-704)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Incorrect Type Conversion or Cast vulnerabilities

Spotted an error? Tell us.