Automate VX: Cleartext Transmission of Sensitive Information

CVE-2025-47419 is a critical-severity cleartext transmission of sensitive information vulnerability in Automate VX from Crestron, with a CVSS 4.0 base score of 10.0 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Automate VX versions: 5.6.8161.21536 through 6.4.0.49. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.3% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of Automate VX you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CrestronAutomate VX5.6.8161.21536 through 6.4.0.49Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
HighSerious loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
HighSerious loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA.

Official description

Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic. The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Cleartext Transmission of Sensitive Information

The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

How developers prevent this class of flaw

  • Before transmitting, encrypt the data using reliable, confidentiality-protecting cryptographic protocols.
  • When using web applications with SSL, use SSL for the entire session from login to logout, not just for the initial login page.
  • When designing hardware platforms, ensure that approved encryption algorithms (such as those recommended by NIST) protect paths from security critical data to trusted user applications.

More Cleartext Transmission of Sensitive Information vulnerabilities (CWE-319)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Cleartext Transmission of Sensitive Information vulnerabilities

Spotted an error? Tell us.