CyberSecBulletin
CVE-2025-48981NVD status: Deferred

CGM MEDICO: Missing Encryption of Sensitive Data

CVE-2025-48981 is a high-severity missing encryption of sensitive data vulnerability in CGM MEDICO from CompuGroup Medical, with a CVSS 3.1 base score of 8.6 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 29.1 as the first without the flaw, so updating CGM MEDICO to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.12% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update CGM MEDICO to 29.1 or a later version.
  2. Read the advisory on cgm.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CompuGroup MedicalCGM MEDICO29.0 up to, but not including, 29.129.1

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
LowLimited modification of data is possible.
Availability
LowPerformance or availability is reduced.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L. Scored by CISA (ADP).

Official description

An insecure implementation of the proprietary protocol DNET in Product CGM MEDICO allows attackers within the intranet to eavesdrop and manipulate data on the protocol because encryption is optional for this connection.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Missing Encryption of Sensitive Data

The product does not encrypt sensitive or critical information before storage or transmission.

How developers prevent this class of flaw

  • Clearly specify which data or resources are valuable enough that they should be protected by encryption. Require that any transmission or storage of this data/resource should use well-vetted encryption algorithms.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
  • When using industry-approved techniques, use them correctly. Don't cut corners by skipping resource-intensive steps (CWE-325). These steps are often essential for preventing common attacks.

More Missing Encryption of Sensitive Data vulnerabilities (CWE-311)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Missing Encryption of Sensitive Data vulnerabilities

Spotted an error? Tell us.