CyberSecBulletin
CVE-2025-55227NVD status: Analyzed

Microsoft SQL Server 2016 Service Pack 3 (GDR): Improper Neutralization of Special Elements used in a Command

CVE-2025-55227 is a high-severity improper neutralization of special elements used in a command vulnerability in Microsoft SQL Server 2016 Service Pack 3 (GDR) from Microsoft, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version 13.0.6470.1 as the first without the flaw, so updating Microsoft SQL Server 2016 Service Pack 3 (GDR) to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 1.42% chance of exploitation within 30 days, higher than 73% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Microsoft SQL Server 2016 Service Pack 3 (GDR) to 13.0.6470.1 or a later version.
  2. Update Microsoft SQL Server 2016 Service Pack 3 Azure Connect Feature Pack to 13.0.7065.1 or a later version.
  3. Update Microsoft SQL Server 2017 (CU 31) to 14.0.3505.1 or a later version.
  4. Read the advisory on msrc.microsoft.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
MicrosoftMicrosoft SQL Server 2016 Service Pack 3 (GDR)13.0.0 up to, but not including, 13.0.6470.113.0.6470.1
MicrosoftMicrosoft SQL Server 2016 Service Pack 3 Azure Connect Feature Pack13.0.0 up to, but not including, 13.0.7065.113.0.7065.1
MicrosoftMicrosoft SQL Server 2017 (CU 31)14.0.0 up to, but not including, 14.0.3505.114.0.3505.1
MicrosoftMicrosoft SQL Server 2017 (GDR)14.0.0 up to, but not including, 14.0.2085.114.0.2085.1
MicrosoftMicrosoft SQL Server 2019 (CU 32)15.0.0.0 up to, but not including, 15.0.4445.115.0.4445.1
MicrosoftMicrosoft SQL Server 2019 (GDR)15.0.0 up to, but not including, 15.0.2145.115.0.2145.1
MicrosoftMicrosoft SQL Server 2022 (CU 20)16.0.0.0 up to, but not including, 16.0.4212.116.0.4212.1
MicrosoftMicrosoft SQL Server 2022 (GDR)16.0.0 up to, but not including, 16.0.1150.116.0.1150.1
MicrosoftSQL Server 201613.0.6300.2 up to, but not including, 13.0.6470.1; 13.0.7000.253 up to, but not including, 13.0.7065.113.0.6470.1, 13.0.7065.1
MicrosoftSQL Server 201714.0.1000.169 up to, but not including, 14.0.2085.1; 14.0.3006.16 up to, but not including, 14.0.3505.114.0.2085.1, 14.0.3505.1
MicrosoftSQL Server 201915.0.2000.5 up to, but not including, 15.0.2145.1; 15.0.4003.23 up to, but not including, 15.0.4445.115.0.2145.1, 15.0.4445.1
MicrosoftSQL Server 202216.0.1000.6 up to, but not including, 16.0.1150.1; 16.0.4003.1 up to, but not including, 16.0.4212.116.0.1150.1, 16.0.4212.1

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (microsoft.com).

Official description

Improper neutralization of special elements used in a command ('command injection') in SQL Server allows an authorized attacker to elevate privileges over a network.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Microsoft SQL Server 2016 Service Pack 3 (GDR)

All Microsoft SQL Server 2016 Service Pack 3 (GDR) vulnerabilities

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.