CyberSecBulletin
CVE-2025-59470NVD status: Analyzed

Backup and Recovery: Improper Neutralization of Special Elements used in a Command

CVE-2025-59470 is a critical-severity improper neutralization of special elements used in a command vulnerability in Backup and Recovery from Veeam, with a CVSS 3.1 base score of 9.0 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected Backup and Recovery versions: 13.0.0 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.53% chance of exploitation within 30 days, higher than 75% of scored CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update Veeam Backup & Replication to 13.0.1.1071 or a later version.
  2. Read the advisory on veeam.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
VeeamBackup and Recovery13.0.0 and earlierNot stated
VeeamVeeam Backup & Replication13.0.0.4967 up to, but not including, 13.0.1.107113.0.1.1071

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
LowPerformance or availability is reduced.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L. Scored by CNA (hackerone.com).

Official description

This vulnerability allows a Backup Operator to perform remote code execution (RCE) as the postgres user by sending a malicious interval or order parameter.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Backup and Recovery

All Backup and Recovery vulnerabilities

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.