CyberSecBulletin
CVE-2025-5965NVD status: Analyzed

Infra Monitoring: Improper Neutralization of Special Elements used in an OS Command

CVE-2025-5965 is a high-severity improper neutralization of special elements used in an OS command vulnerability in Infra Monitoring from Centreon, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. The record lists versions 25.10.2, 24.10.15, 24.04.19 as the first without the flaw, so updating Infra Monitoring to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 28% chance of exploitation within 30 days, which is in the top 1.87% of all scored CVEs.

Patch this week

EPSS places it among the vulnerabilities most likely to be exploited soon.

What to do

  1. Update Infra Monitoring to 25.10.2 or 24.10.15 or 24.04.19, whichever matches your release line, or a later version.
  2. Update Centreon Web to 24.04.19 or 24.10.15 or 25.10.2, whichever matches your release line, or a later version.
  3. Read the advisory on thewatch.centreon.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
CentreonInfra Monitoring25.10.0 up to, but not including, 25.10.2; 24.10.0 up to, but not including, 24.10.15; 24.04.0 up to, but not including, 24.04.1925.10.2, 24.10.15, 24.04.19
CentreonCentreon Web24.04.0 up to, but not including, 24.04.19; 24.10.0 up to, but not including, 24.10.15; 25.10.0 up to, but not including, 25.10.224.04.19, 24.10.15, 25.10.2

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by CNA.

Official description

In the backup parameters, a user with high privilege is able to concatenate custom instructions to the backup setup. Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Backup configuration in the administration setup modules) allows OS Command Injection.This issue affects Infra Monitoring: from 25.10.0 before 25.10.2, from 24.10.0 before 24.10.15, from 24.04.0 before 24.04.19.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Patches and release notes

Other vulnerabilities in Infra Monitoring

All Infra Monitoring vulnerabilities

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.