CyberSecBulletin
CVE-2025-66050NVD status: Analyzed

IP7137: Use of Default Password

CVE-2025-66050 is a critical-severity use of default password vulnerability in IP7137 from Vivotek, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected IP7137 versions: 0200a. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.39% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of IP7137 you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
VivotekIP71370200aNot stated
VivotekIp7137 Firmware0200aNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.09.3CriticalCNA (cert.pl)
CVSS 3.19.8CriticalNVD

Official description

Vivotek IP7137 camera with firmware version 0200a by default dos not require to provide any password when logging in as an administrator. While it is possible to set up such a password, a user is not informed about such a need. The vendor has not replied to the CNA. Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Default Password

The product uses default passwords for potentially critical functionality.

How developers prevent this class of flaw

  • Prohibit use of default, hard-coded, or other values that do not vary for each installation of the product - especially for separate organizations.
  • Ensure that product documentation clearly emphasizes the presence of default passwords and provides steps for the administrator to change them.
  • Force the administrator to change the credential upon installation.

More Use of Default Password vulnerabilities (CWE-1393)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Other vulnerabilities in IP7137

All IP7137 vulnerabilities

Recent Use of Default Password vulnerabilities

Spotted an error? Tell us.