CyberSecBulletin
CVE-2025-6949NVD status: Deferred

EDR-G9010 Series: Execution with Unnecessary Privileges

CVE-2025-6949 is a critical-severity execution with unnecessary privileges vulnerability in EDR-G9010 Series from Moxa, with a CVSS 4.0 base score of 9.3 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected EDR-G9010 Series versions: 1.0 through 3.14. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.53% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of EDR-G9010 Series you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on moxa.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
MoxaEDR-G9010 Series1.0 through 3.14Not stated
MoxaEDR-8010 Series1.0 through 3.17Not stated
MoxaEDF-G1002-BP Series1.0 through 3.17Not stated
MoxaTN-4900 Series1.0 through 3.14Not stated
MoxaNAT-102 Series1.0 through 3.17Not stated
MoxaNAT-108 Series1.0 through 3.16Not stated
MoxaOnCell G4302-LTE4 Series1.0 through 3.13Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
HighSerious loss of availability on the vulnerable system.
Confidentiality (other systems)
NoneNo loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
NoneNo loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
HighSerious loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (moxa.com).

Official description

An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Execution with Unnecessary Privileges

The product performs an operation at a privilege level that is higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses.

How developers prevent this class of flaw

  • Run your code using the lowest privileges that are required to accomplish the necessary tasks. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.
  • Identify the functionality that requires additional privileges, such as access to privileged operating system resources. Wrap and centralize this functionality if possible, and isolate the privileged code as much as possible from other code. Raise privileges as late as possible, and drop them as soon as possible to avoid CWE-271. Avoid weaknesses such as CWE-288 and CWE-420 by protecting all possible communication channels that could interact with the privileged code, such as a secondary socket that is only intended to be accessed by administrators.
  • Identify the functionality that requires additional privileges, such as access to privileged operating system resources. Wrap and centralize this functionality if possible, and isolate the privileged code as much as possible from other code. Raise privileges as late as possible, and drop them as soon as possible to avoid CWE-271. Avoid weaknesses such as CWE-288 and CWE-420 by protecting all possible communication channels that could interact with the privileged code, such as a secondary socket that is only intended to be accessed by administrators.

More Execution with Unnecessary Privileges vulnerabilities (CWE-250)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in EDR-G9010 Series

All EDR-G9010 Series vulnerabilities

Recent Execution with Unnecessary Privileges vulnerabilities

Spotted an error? Tell us.