I24 Firmware: Use of Hard-coded Password
CVE-2025-70798 is a high-severity use of hard-coded password vulnerability in I24 Firmware from Tenda, with a CVSS 3.1 base score of 8.4 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, without any action from a user. Affected I24 Firmware versions: 3.0.0.5. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.21% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of I24 Firmware you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Tenda | I24 Firmware | 3.0.0.5 | Not stated |
Version data comes from NVD's product matching. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CISA (ADP).
Official description
Tenda i24V3.0si V3.0.0.5 Firmware V3.0.0.5 was discovered to contain a hardcoded password vulnerability in /etc_ro/shadow, which allows attackers to log in as root.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Use of Hard-coded Password
The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound authentication to external components.
How developers prevent this class of flaw
- For outbound authentication: store passwords outside of the code in a strongly-protected, encrypted configuration file or database that is protected from access by all outsiders, including other local users on the same system. Properly protect the key (CWE-320). If you cannot use encryption to protect the file, then make sure that the permissions are as restrictive as possible.
- For inbound authentication: Rather than hard-code a default username and password for first time logins, utilize a first login mode that requires the user to enter a unique strong password.
- Perform access control checks and limit which entities can access the feature that requires the hard-coded password. For example, a feature might only be enabled through the system console instead of through a network connection.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Technical write-ups (may include proof of concept)
- github.com/vuln-1/vuln/blob/main/Tenda/i24V3.0si_V3.0.0.5/report-1.mdExploit, Third Party Advisory
Other references
- tendacn.com/Product
Other vulnerabilities in I24 Firmware