CyberSecBulletin
CVE-2025-7884NVD status: Analyzed

Control Center: Insufficient Verification of Data Authenticity

CVE-2025-7884 is a high-severity insufficient verification of data authenticity vulnerability in Control Center from Eluktronics, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. Affected Control Center versions: 5.23.51.41. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.14% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Control Center you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
EluktronicsControl Center5.23.51.41Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.01.9LowCNA (vuldb.com)
CVSS 3.13.3LowCNA (vuldb.com)
CVSS 3.17.8HighNVD
CVSS 2.01.7LowCNA (vuldb.com)

Official description

A vulnerability classified as problematic was found in Eluktronics Control Center 5.23.51.41. Affected by this vulnerability is an unknown functionality of the component REG File Handler. The manipulation leads to insufficient verification of data authenticity. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Insufficient Verification of Data Authenticity

The product does not sufficiently verify the origin or authenticity of data, in a way that causes it to accept invalid data.

More Insufficient Verification of Data Authenticity vulnerabilities (CWE-345)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).