CyberSecBulletin
CVE-2025-7952NVD status: Analyzed

T6: Improper Neutralization of Special Elements in Output Used by a Downstream Component

CVE-2025-7952 is a high-severity improper neutralization of special elements in output used by a downstream component vulnerability in T6 from TOTOLINK, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected T6 versions: 4.1.5cu.748. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 24.5% chance of exploitation within 30 days, which is in the top 2.09% of all scored CVEs.

Patch this week

EPSS places it among the vulnerabilities most likely to be exploited soon.

What to do

  1. Check which version of T6 you run against the affected versions below, and install the vendor's latest release.

Affected products and versions

VendorProductAffected versionsFixed in
TOTOLINKT64.1.5cu.748Not stated
TOTOLINKT6 Firmwarev4.1.5cu.748_b20211015Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.02.1LowCNA (vuldb.com)
CVSS 3.16.3MediumCNA (vuldb.com)
CVSS 3.18.8HighNVD
CVSS 2.06.5MediumCNA (vuldb.com)

Official description

A vulnerability classified as critical was found in TOTOLINK T6 4.1.5cu.748. This vulnerability affects the function ckeckKeepAlive of the file wireless.so of the component MQTT Packet Handler. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements in Output Used by a Downstream Component

The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.

How developers prevent this class of flaw

  • Programming languages and supporting technologies might be chosen which are not subject to these issues.
  • Utilize an appropriate mix of allowlist and denylist parsing to filter control-plane syntax from all input.

More Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities (CWE-74)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Third-party and government advisories

Technical write-ups (may include proof of concept)

Other references

Other vulnerabilities in T6

All T6 vulnerabilities

Recent Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities

Spotted an error? Tell us.