N350R: Improper Neutralization of Special Elements in Output Used by a Downstream Component
CVE-2025-8937 is a high-severity improper neutralization of special elements in output used by a downstream component vulnerability in N350R from TOTOLINK, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected N350R versions: 1.2.3-B20130826. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 2.17% chance of exploitation within 30 days, higher than 83% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of N350R you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| TOTOLINK | N350R | 1.2.3-B20130826 | Not stated |
| TOTOLINK | N350r Firmware | 1.2.3-b20130826 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 2.1 | Low | CNA (vuldb.com) |
| CVSS 3.1 | 6.3 | Medium | CNA (vuldb.com) |
| CVSS 3.1 | 8.8 | High | NVD |
| CVSS 2.0 | 6.5 | Medium | CNA (vuldb.com) |
Official description
A vulnerability has been found in TOTOLINK N350R 1.2.3-B20130826. This vulnerability affects unknown code of the file /boafrm/formSysCmd. The manipulation leads to command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements in Output Used by a Downstream Component
The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
How developers prevent this class of flaw
- Programming languages and supporting technologies might be chosen which are not subject to these issues.
- Utilize an appropriate mix of allowlist and denylist parsing to filter control-plane syntax from all input.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- vuldb.com/?id.319900Third Party Advisory, VDB Entry
- vuldb.com/?submit.631826Third Party Advisory, VDB Entry
- vuldb.com/?submit.631838Third Party Advisory, VDB Entry
Other references
- vuldb.com/?ctiid.319900Permissions Required, VDB Entry
- totolink.net/Product
Recent Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.