Imaris Viewer: Access of Uninitialized Pointer
CVE-2025-9274 is a high-severity access of uninitialized pointer vulnerability in Imaris Viewer from Oxford Instruments, with a CVSS 3.0 base score of 7.8 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Imaris Viewer versions: 10.0.1. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.23% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of Imaris Viewer you run against the affected versions below, and install the vendor's latest release.
- Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Oxford Instruments | Imaris Viewer | 10.0.1 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- LocalThe attacker needs local access or must trick a user into running something.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- RequiredA user must take an action such as opening a file or link.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (trendmicro.com).
Official description
Oxford Instruments Imaris Viewer IMS File Parsing Uninitialized Pointer Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Oxford Instruments Imaris Viewer. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of IMS files. The issue results from the lack of proper initialization of a pointer prior to accessing it. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-21657.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Access of Uninitialized Pointer
The product accesses or uses a pointer that has not been initialized.
More Access of Uninitialized Pointer vulnerabilities (CWE-824)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- zerodayinitiative.com/advisories/ZDI-25-853/Third Party Advisory
Other vulnerabilities in Imaris Viewer
- 7.8 High severity
Recent Access of Uninitialized Pointer vulnerabilities
- 8.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
- 7.8 High severity
Spotted an error? Tell us.