RE6250: Improper Neutralization of Special Elements used in a Command
CVE-2025-9575 is a high-severity improper neutralization of special elements used in a command vulnerability in RE6250 from Linksys, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. Affected RE6250 versions: 1.0.013.001; 1.0.04.001; 1.0.04.002, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 6.94% chance of exploitation within 30 days, which is in the top 5.79% of all scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of RE6250 you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Linksys | RE6250 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | RE6300 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | RE6350 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | RE6500 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | RE7000 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | RE9000 | 1.0.013.001; 1.0.04.001; 1.0.04.002; 1.1.05.003; 1.2.07.001 | Not stated |
| Linksys | Re6250 Firmware | 1.0.04.001 | Not stated |
| Linksys | Re6300 Firmware | 1.2.07.001 | Not stated |
| Linksys | Re6350 Firmware | 1.0.04.001 | Not stated |
| Linksys | Re7000 Firmware | 1.1.05.003 | Not stated |
| Linksys | Re9000 Firmware | 1.0.04.002 | Not stated |
| Linksys | Re6500 Firmware | 1.0.013.001 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 2.1 | Low | CNA (vuldb.com) |
| CVSS 3.1 | 6.3 | Medium | CNA (vuldb.com) |
| CVSS 3.1 | 8.8 | High | NVD |
| CVSS 2.0 | 6.5 | Medium | CNA (vuldb.com) |
Official description
A vulnerability was determined in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. This issue affects the function cgiMain of the file /cgi-bin/upload.cgi. Executing manipulation of the argument filename can lead to os command injection. The attack may be performed from a remote location. The exploit has been publicly disclosed and may be utilized. The vendor was contacted early about this disclosure but did not respond in any way.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Third-party and government advisories
- vuldb.com/?id.321689Third Party Advisory, VDB Entry
- vuldb.com/?submit.634840Third Party Advisory, VDB Entry
Technical write-ups (may include proof of concept)
- github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_13/13.mdExploit, Third Party Advisory
- github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_13/13.md#pocExploit, Third Party Advisory
Other references
- vuldb.com/?ctiid.321689Permissions Required, VDB Entry
- linksys.com/Product
Other vulnerabilities in RE6250
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
- 8.8 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 9.8 Critical severity
- 9.8 Critical severity
- 9.8 Critical severity
- 7.2 High severity
- 9.8 Critical severity
- 9.8 Critical severity
Spotted an error? Tell us.