CyberSecBulletin
CVE-2026-102676NVD status: Analyzed

electron: Improper Privilege Management

CVE-2026-102676 is a critical-severity improper privilege management vulnerability in electron, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected electron versions: < 41.10.6; >= 42.0.0-alpha.1, < 42.9.2; >= 43.0.0-alpha.1, < 43.4.1, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.48% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of electron you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on github.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
Electronelectron< 41.10.6; >= 42.0.0-alpha.1, < 42.9.2; >= 43.0.0-alpha.1, < 43.4.1; >= 44.0.0-alpha.1, < 44.0.0-beta.5Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.18.3HighCNA (github.com)
CVSS 3.19.8CriticalNVD

Official description

Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to 41.10.6, 42.9.2, 43.4.1, and 44.0.0-beta.5, an Electron <webview> guest could enable nodeIntegrationInWorker for its Web Workers even when the unsandboxed embedder had Node.js integration disabled, allowing untrusted guest content to create a Node-enabled worker with more privilege than the embedder granted. Applications that do not enable the <webview> tag or that keep the embedder sandboxed are not affected. This issue is fixed in versions 41.10.6, 42.9.2, 43.4.1, and 44.0.0-beta.5.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Privilege Management

The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.

How developers prevent this class of flaw

  • Very carefully manage the setting, management, and handling of privileges. Explicitly manage trust zones in the software.
  • Follow the principle of least privilege when assigning access rights to entities in a software system.
  • Consider following the principle of separation of privilege. Require multiple conditions to be met before permitting access to a system resource.

More Improper Privilege Management vulnerabilities (CWE-269)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in electron

All electron vulnerabilities

Recent Improper Privilege Management vulnerabilities

Spotted an error? Tell us.