CyberSecBulletin
CVE-2026-105979NVD status: Deferred

TK100: Improper Neutralization of Special Elements used in a Command

CVE-2026-105979 is a high-severity improper neutralization of special elements used in a command vulnerability in TK100 from Welotec, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. The record lists version 3.5.116 as the first without the flaw, so updating TK100 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.36% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update TK100 to 3.5.116 or a later version.
  2. Update TK500-v2 to 1.0.124 or a later version.
  3. Update TK500-v3 to 1.0.123 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
WelotecTK100before 3.5.1163.5.116
WelotecTK500-v2before 1.0.1241.0.124
WelotecTK500-v3before 1.0.1231.0.123

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
HighAdministrator-level access is required first.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (cert.vde.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.6HighCNA (cert.vde.com)
CVSS 3.17.2HighCNA (cert.vde.com)

Official description

Improper input validation in the ZeroTier VPN function may allow a remote attacker with high privileges to inject system commands and execute them with root privileges.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in a Command

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • If possible, ensure that all external commands called from the program are statically created.
  • Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.

More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in TK100

All TK100 vulnerabilities

Recent Improper Neutralization of Special Elements used in a Command vulnerabilities

Spotted an error? Tell us.