CyberSecBulletin
CVE-2026-10696NVD status: Analyzed

UniGetUI: Use of Incorrectly-Resolved Name or Reference

CVE-2026-10696 is a high-severity use of incorrectly-resolved name or reference vulnerability in UniGetUI from Devolutions, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected UniGetUI versions: 2026.2.1 and earlier. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.27% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of UniGetUI you run against the affected versions below, and install the vendor's latest release.
  2. Read the advisory on devolutions.net for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
DevolutionsUniGetUI2026.2.1 and earlierNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by CISA (ADP).

Official description

Use of an incorrectly resolved name or reference in the pinget backend in Devolutions UniGetUI 2026.2.0 and earlier allows a WinGet community catalog contributor to cause an installed application to be correlated to an unrelated, attacker-controlled catalog package and to execute an attacker-controlled installer via a crafted catalog package whose normalized name is contained as a substring within the installed application name when a user applies the proposed update.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Use of Incorrectly-Resolved Name or Reference

The product uses a name or reference to access a resource, but the name/reference resolves to a resource that is outside of the intended control sphere.

More Use of Incorrectly-Resolved Name or Reference vulnerabilities (CWE-706)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Use of Incorrectly-Resolved Name or Reference vulnerabilities