Mendix Studio Pro 11: Binding to an Unrestricted IP Address

CVE-2026-112136 is a high-severity binding to an unrestricted IP address vulnerability in Mendix Studio Pro 11 from Siemens, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. The record lists version V11.16.0 as the first without the flaw, so updating Mendix Studio Pro 11 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.3% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Mendix Studio Pro 11 to V11.16.0 or a later version.
  2. Update Mendix Studio Pro 11.12 to V11.12.7 or a later version.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  4. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensMendix Studio Pro 11V11.15.0 up to, but not including, V11.16.0V11.16.0
SiemensMendix Studio Pro 11.12V11.12.6 up to, but not including, V11.12.7V11.12.7

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (siemens.com).

Scoring systemScoreSeverityScored by
CVSS 4.09.2CriticalCNA (siemens.com)
CVSS 3.18.8HighCNA (siemens.com)

Official description

A vulnerability has been identified in Mendix Studio Pro 11 (All versions >= V11.15.0 < V11.16.0), Mendix Studio Pro 11.12 (All versions >= V11.12.6 < V11.12.7). The affected products MCP Server does not properly restrict its HTTP listener to the loopback interface, leaving it potentially exposed to remote systems. This could allow an attacker with network access to interact with the MCP Server remotely.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Binding to an Unrestricted IP Address

The product assigns the address 0.0.0.0 for a database server, a cloud service/instance, or any computing resource that communicates remotely.

How developers prevent this class of flaw

  • Assign IP addresses that are not 0.0.0.0.
  • Unwanted connections to the configured server may be denied through a firewall or other packet filtering measures.

More Binding to an Unrestricted IP Address vulnerabilities (CWE-1327)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Binding to an Unrestricted IP Address vulnerabilities

Spotted an error? Tell us.