CVE-2026-112357NVD status: Awaiting Analysis

GFI KerioConnect: Incorrect Default Permissions

CVE-2026-112357 is a high-severity incorrect default permissions vulnerability in GFI KerioConnect from GFI USA, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 10.0.9p2 as the first without the flaw, so updating GFI KerioConnect to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.13% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update GFI KerioConnect to 10.0.9p2 or a later version.

Affected products and versions

VendorProductAffected versionsFixed in
GFI USAGFI KerioConnectbefore 10.0.9p210.0.9p2

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (vulncheck.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.5HighCNA (vulncheck.com)
CVSS 3.17.8HighCNA (vulncheck.com)

Official description

GFI KerioConnect (Kerio Connect) Outlook Connector (Offline Edition), 'KOFF', before 10.0.9 Patch 2 contains a local privilege escalation vulnerability caused by weak installer permissions that leave the product directory writable by the built-in Users group. A local non-administrative attacker can replace the searchd.exe service binary used by the bundled KOFFIndexingService, which runs as LocalSystem, to execute arbitrary code with NT AUTHORITY\SYSTEM privileges upon the next service start or reboot.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Incorrect Default Permissions

During installation, installed file permissions are set to allow anyone to modify those files.

How developers prevent this class of flaw

  • The architecture needs to access and modification attributes for files to only those users who actually require those actions.
  • Compartmentalize the system to have safe areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area. Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.

More Incorrect Default Permissions vulnerabilities (CWE-276)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).