CyberSecBulletin
CVE-2026-18848NVD status: Analyzed

Power Systems Firmware: Cross-Site Request Forgery

CVE-2026-18848 is a high-severity cross-site request forgery vulnerability in Power Systems Firmware from IBM, with a CVSS 3.1 base score of 8.3 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Power Systems Firmware versions: FW1120.00; FW1110.00 through FW1110.30; FW1060.00 through FW1060.80, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.15% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Power System E1080 (9080-hex) Firmware to fw1060.81 or a later version.
  2. Update Power System E1180 (9080-heu) Firmware to fw1110.31 or a later version.
  3. Update Power System S922 (9009-22g) Firmware to fw950.h3 or a later version.
  4. Read the advisory on ibm.com for workarounds and exact fixed builds.
  5. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  6. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
IBMPower Systems FirmwareFW1120.00; FW1110.00 through FW1110.30; FW1060.00 through FW1060.80; FW950.00 through FW950.H2Not stated
IBMPower System E1080 (9080-hex) Firmwarefw1060.00 up to, but not including, fw1060.81fw1060.81
IBMPower System E1180 (9080-heu) Firmwarefw1110.00 up to, but not including, fw1110.31; fw1120.00fw1110.31
IBMPower System S922 (9009-22g) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System H922 (9223-22s) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System S914 (9009-41g) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System S924 (9009-42g) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System H924 (9223-42s) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System E950 (9040-mr9) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3
IBMPower System E980 (9080-m9s) Firmwarefw950.00 up to, but not including, fw950.h3fw950.h3

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
LowSome restricted data can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:H/A:H. Scored by CNA (us.ibm.com).

Official description

IBM Power Systems Firmware FW1120.00, FW1110.00 through FW1110.30, FW1060.00 through FW1060.80, and FW950.00 through FW950.H2 is affected by a vulnerability in the ASMI web interface. An attacker who can lure a logged-in ASMI administrator to visit a crafted web page can, under specific conditions, silently perform administrative actions on the FSP on behalf of that administrator, resulting in a confidentiality, integrity, and availability impact to the managed system.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Cross-Site Request Forgery

The web application does not, or cannot, sufficiently verify whether a request was intentionally provided by the user who sent the request, which could have originated from an unauthorized actor.

How developers prevent this class of flaw

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, use anti-CSRF packages such as the OWASP CSRFGuard. Another example is the ESAPI Session Management control, which includes a component for CSRF.
  • Ensure that the application is free of cross-site scripting issues (CWE-79), because most CSRF defenses can be bypassed using attacker-controlled script.
  • Generate a unique nonce for each form, place the nonce into the form, and verify the nonce upon receipt of the form. Be sure that the nonce is not predictable (CWE-330).

More Cross-Site Request Forgery vulnerabilities (CWE-352)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).