CyberSecBulletin
CVE-2026-19003NVD status: Analyzed

BI Connector ODBC Driver: Stack-based Buffer Overflow

CVE-2026-19003 is a high-severity stack-based buffer overflow vulnerability in BI Connector ODBC Driver from MongoDB, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. The record lists version 1.4.9 as the first without the flaw, so updating BI Connector ODBC Driver to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.21% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update BI Connector ODBC Driver to 1.4.9 or a later version.
  2. Read the advisory on github.com for workarounds and exact fixed builds.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
MongoDBBI Connector ODBC Driver1.0.0 up to, but not including, 1.4.91.4.9

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (mongodb.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.4HighCNA (mongodb.com)
CVSS 3.17.8HighCNA (mongodb.com)

Official description

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Stack-based Buffer Overflow

The product writes past the end of a buffer that was allocated on the stack.

How developers prevent this class of flaw

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking. D3-SFCV (Stack Frame Canary Validation) from D3FEND discusses canary-based detection in detail.
  • Use an abstraction library to abstract away risky APIs. Not a complete solution.
  • Implement and perform bounds checking on input.

More Stack-based Buffer Overflow vulnerabilities (CWE-121)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in BI Connector ODBC Driver

All BI Connector ODBC Driver vulnerabilities

Recent Stack-based Buffer Overflow vulnerabilities

Spotted an error? Tell us.