CyberSecBulletin
CVE-2026-19667NVD status: Awaiting Analysis

BIND 9: Numeric Truncation Error

CVE-2026-19667 is a high-severity numeric truncation error vulnerability in BIND 9 from ISC, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected BIND 9 versions: 9.11.0 through 9.18.50; 9.20.0 through 9.20.27; 9.21.0 through 9.21.25, and others listed below. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.57% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of BIND 9 you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
ISCBIND 99.11.0 through 9.18.50; 9.20.0 through 9.20.27; 9.21.0 through 9.21.25; 9.11.3-S1 through 9.18.50-S1; 9.20.9-S1 through 9.20.27-S1Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
NoneNo data is disclosed.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by CNA (isc.org).

Official description

If an attacker-controlled authoritative server can produce a negative answer that is exactly 65536 bytes, then a flaw in `named` results in a negative cache entry of 0 bytes. When this entry is subsequently read, `named` aborts. This issue affects BIND 9 versions 9.11.0 through 9.18.50, 9.20.0 through 9.20.27, 9.21.0 through 9.21.25, 9.11.3-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.27-S1.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Numeric Truncation Error

Truncation errors occur when a primitive is cast to a primitive of a smaller size and data is lost in the conversion.

How developers prevent this class of flaw

  • Ensure that no casts, implicit or explicit, take place that move from a larger size primitive or a smaller size primitive.

More Numeric Truncation Error vulnerabilities (CWE-197)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in BIND 9

All BIND 9 vulnerabilities

Recent Numeric Truncation Error vulnerabilities

Spotted an error? Tell us.