CH7: Improper Neutralization of Special Elements in Output Used by a Downstream Component
CVE-2026-19747 is a critical-severity improper neutralization of special elements in output used by a downstream component vulnerability in CH7 from Tenda, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected CH7 versions: 20260625. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 3.06% chance of exploitation within 30 days, higher than 88% of scored CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of CH7 you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Tenda | CH7 | 20260625 | Not stated |
| Tenda | CH7G | 20260625 | Not stated |
| Tenda | CH10 | 20260625 | Not stated |
| Tenda | CP3 | 20260625 | Not stated |
| Tenda | CP3 Pro | 20260625 | Not stated |
| Tenda | CP7 | 20260625 | Not stated |
| Tenda | TC3B14C | 20260625 | Not stated |
| Tenda | TC3B15C | 20260625 | Not stated |
| Tenda | TC3T14C | 20260625 | Not stated |
| Tenda | TC3T15C | 20260625 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (vuldb.com).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 8.9 | High | CNA (vuldb.com) |
| CVSS 3.1 | 9.8 | Critical | CNA (vuldb.com) |
| CVSS 2.0 | 10.0 | High | CNA (vuldb.com) |
Official description
A weakness has been identified in Tenda CH7, CH7G, CH10, CP3, CP3 Pro, CP7, TC3B14C, TC3B15C, TC3T14C and TC3T15C up to 20260625. This impacts the function CAte::HandleCmd of the file Kylin of the component ATE Module. This manipulation causes command injection. The attack is possible to be carried out remotely.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements in Output Used by a Downstream Component
The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
How developers prevent this class of flaw
- Programming languages and supporting technologies might be chosen which are not subject to these issues.
- Utilize an appropriate mix of allowlist and denylist parsing to filter control-plane syntax from all input.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Recent Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities
- 7.3 High severity
- 7.2 High severity
- 8.7 High severity
- 7.3 High severity
- 7.3 High severity
- 7.3 High severity
Spotted an error? Tell us.