WISE-6610-NB: Improper Neutralization of Special Elements used in a Command
CVE-2026-2670 is a high-severity improper neutralization of special elements used in a command vulnerability in WISE-6610-NB from Advantech, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected WISE-6610-NB versions: 1.2.1_20251110. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 13.7% chance of exploitation within 30 days, which is in the top 3.44% of all scored CVEs.
EPSS places it among the vulnerabilities most likely to be exploited soon.
What to do
- Check which version of WISE-6610-NB you run against the affected versions below, and install the vendor's latest release.
- Read the advisory on advantech.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Advantech | WISE-6610-NB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-TB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-JB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-CB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EL-NB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EL-EB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EL-TB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EL-JB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610-EL-CB | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610P-DEA | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610P-DNA | 1.2.1_20251110 | Not stated |
| Advantech | WISE-6610P-DTA | 1.2.1_20251110 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (vuldb.com).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 7.3 | High | CNA (vuldb.com) |
| CVSS 3.1 | 7.2 | High | CNA (vuldb.com) |
| CVSS 2.0 | 8.3 | High | CNA (vuldb.com) |
Official description
A vulnerability was identified in Advantech WISE-6610-NB, WISE-6610-EB, WISE-6610-TB, WISE-6610-JB, WISE-6610-CB, WISE-6610-EL-NB, WISE-6610-EL-EB, WISE-6610-EL-TB, WISE-6610-EL-JB, WISE-6610-EL-CB, WISE-6610P-DEA, WISE-6610P-DNA and WISE-6610P-DTA 1.2.1_20251110. Affected is an unknown function of the file /cgi-bin/luci/admin/openvpn_apply of the component Background Management. Such manipulation of the argument delete_file leads to os command injection. The attack can be executed remotely. The exploit is publicly available and might be used. Upgrading to version 1.2.4_20260821 is able to address this issue. It is advisable to upgrade the affected component. The vendor explains: "The delete operation has been redesigned to map the requested file type to a fixed allowlisted path, require a numeric tunnel ID, reject invalid requests, and use the native filesystem API (fs.unlink) instead of constructing a shell command from request data."
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Other references
Other vulnerabilities in WISE-6610-NB
- 9.9 Critical severity
- 9.9 Critical severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 7.8 High severity
- 7.8 High severity
- 7.3 High severity
- 7.2 High severity
- 7.3 High severity
- 7.2 High severity
Spotted an error? Tell us.