Connext Professional: Out-of-bounds Read

CVE-2026-3894 is a critical-severity out-of-bounds read vulnerability in Connext Professional from RTI, with a CVSS 3.1 base score of 9.1 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists versions 7.7.0, 7.3.1.3, 6.1.* as the first without the flaw, so updating Connext Professional to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.2% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Update Connext Professional to 7.7.0 or 7.3.1.3 or 6.1.* or 6.0.*, whichever matches your release line, or a later version.
  2. Read the advisory on rti.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
RTIConnext Professional7.4.0 up to, but not including, 7.7.0; 7.0.0 up to, but not including, 7.3.1.3; 6.1.0 up to, but not including, 6.1.*; 6.0.0 up to, but not including, 6.0.*; 5.3.0 up to, but not including, 5.3.*; 5.2.0 up to, but not including, 5.2.*; 5.0.0 up to, but not including, 5.1.*7.7.0, 7.3.1.3, 6.1.*, 6.0.*, 5.3.*, 5.2.*

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 4.09.2CriticalCNA
CVSS 3.19.1CriticalNVD

Official description

Out-of-bounds Read vulnerability in RTI Connext Professional (Core Libraries) allows Overread Buffers. This issue affects Connext Professional: from 7.4.0 before 7.7.0, from 7.0.0 before 7.3.1.3, from 6.1.0 before 6.1.*, from 6.0.0 before 6.0.*, from 5.3.0 before 5.3.*, from 5.2.0 before 5.2.*, from 5.0.0 before 5.1.*.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Out-of-bounds Read

The product reads data past the end, or before the beginning, of the intended buffer.

How developers prevent this class of flaw

  • Use a language that provides appropriate memory abstractions.

More Out-of-bounds Read vulnerabilities (CWE-125)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Connext Professional

All Connext Professional vulnerabilities

Recent Out-of-bounds Read vulnerabilities

Spotted an error? Tell us.