Multiple connections to the backend using the same charging station ID are allowed, which…
CVE-2026-44383 is a high-severity vulnerability in Le Circuit Electrique charging station backend from Hydro-Québec, with a CVSS 3.1 base score of 7.5 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version June_2026 as the first without the flaw, so updating Le Circuit Electrique charging station backend to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.56% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Le Circuit Electrique charging station backend to June_2026 or a later version.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Hydro-Québec | Le Circuit Electrique charging station backend | before June_2026 | June_2026 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- NoneNo data is disclosed.
- Integrity
- NoneNothing can be modified.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H. Scored by CNA (hq.dhs.gov).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 8.7 | High | CNA (hq.dhs.gov) |
| CVSS 3.1 | 7.5 | High | CNA (hq.dhs.gov) |
Official description
Multiple connections to the backend using the same charging station ID are allowed, which could allow an attacker to deploy multiple instances of malicious OCPP clients to overwhelm the backend.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in Le Circuit Electrique charging station backend
- 7.5 High severity
Spotted an error? Tell us.