EdgeConnect SD-WAN Gateway (ECOS): Improper Neutralization of Special Elements used in a Command
CVE-2026-44879 is a high-severity improper neutralization of special elements used in a command vulnerability in EdgeConnect SD-WAN Gateway (ECOS) from Hewlett Packard Enterprise, with a CVSS 3.1 base score of 7.2 out of 10. It can be exploited remotely over the network by an attacker with administrator privileges, without any action from a user. Affected EdgeConnect SD-WAN Gateway (ECOS) versions: 9.4.0.0 through 9.4.4.0; 9.5.0.0 through 9.5.4.0. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 1.45% chance of exploitation within 30 days, higher than 74% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Check which version of EdgeConnect SD-WAN Gateway (ECOS) you run against the affected versions below, and install the vendor's latest release.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Hewlett Packard Enterprise | EdgeConnect SD-WAN Gateway (ECOS) | 9.4.0.0 through 9.4.4.0; 9.5.0.0 through 9.5.4.0 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- HighAdministrator-level access is required first.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (hpe.com).
Official description
A vulnerability in the command line interface of ECOS devices could allow a highly privileged, authenticated remote attacker to perform command injection on certain CLI commands. Successful exploitation could allow an attacker to execute arbitrary commands on the underlying operating system.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other vulnerabilities in EdgeConnect SD-WAN Gateway (ECOS)
- 7.2 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 9.3 Critical severity
- 7.5 High severity
- 8.0 High severity
- 7.8 High severity
- 8.8 High severity
- 7.1 High severity
Spotted an error? Tell us.