CyberSecBulletin
CVE-2026-4827NVD status: Awaiting Analysis

Easergy MiCOM C264: Insufficient Entropy

CVE-2026-4827 is a high-severity insufficient entropy vulnerability in Easergy MiCOM C264 from Schneider Electric, with a CVSS 4.0 base score of 8.7 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Easergy MiCOM C264 versions: Versions D6.x; Versions D7.33 and prior. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.31% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Easergy MiCOM C264 you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
Schneider ElectricEasergy MiCOM C264Versions D6.x; Versions D7.33 and priorNot stated
Schneider ElectricEasergy C5Version 1.1.17 and priorNot stated
Schneider ElectricEasergy MiCOM P30P139 version prior to P139.678.700; P437 version prior to P437.678.700; P439 version prior to P439.678.700; P532 version prior to P532.678.700; P539 version prior to P539.678.700; P631 version prior to P631.678.700; P632 version prior to P632.678.700; P633 version prior to P633.678.700; and 8 more rangesNot stated
Schneider ElectricEasergy MiCOM P40Not specified in the recordNot stated
Schneider ElectricEcoStruxure™ Power Automation System Gateway (EPAS-GTW)Version 6.4.616.200.100 and priorNot stated
Schneider ElectricEcoStruxure™ Power Automation System User Interface (EPAS-UI)Version 3.0.3 and priorNot stated
Schneider ElectricEcoStruxure™ Power OperationVersion 2022 CU6 and prior; Version 2024 CU2 and priorNot stated
Schneider ElectriciPMFLSVersion 64.2025.0.13 and priorNot stated
Schneider ElectricPowerLogic™ P5 Protection RelayV02.502.103 and priorNot stated
Schneider ElectricPowerLogic™ P7 Protection and Control PlatformV02.002.002 and priorNot stated
Schneider ElectricPowerLogic™ T300Version 2.9.4 and priorNot stated
Schneider ElectricPowerLogic™ T500Version 11.08.02 and priorNot stated
Schneider ElectricSaitel DPVersion 11.06.36 and priorNot stated
Schneider ElectricEasyLogic T150 (formerly Saitel DR)Version 11.06.30 and priorNot stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Attack requirements
NoneThe attack does not depend on a particular deployment or configuration.
Privileges required
NoneNo account or login is needed.
User interaction
PassiveA user only needs to do something routine, such as viewing a page.
Confidentiality (vulnerable system)
HighSerious loss of confidentiality on the vulnerable system.
Integrity (vulnerable system)
HighSerious loss of integrity on the vulnerable system.
Availability (vulnerable system)
LowLimited loss of availability on the vulnerable system.
Confidentiality (other systems)
NoneNo loss of confidentiality on systems beyond the vulnerable one.
Integrity (other systems)
NoneNo loss of integrity on systems beyond the vulnerable one.
Availability (other systems)
NoneNo loss of availability on systems beyond the vulnerable one.

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA (se.com).

Official description

CWE‑331: Insufficient Entropy vulnerability exists that could lead to unauthorized access when an attacker on the network can exploit weaknesses in session‑management protections.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Insufficient Entropy

The product uses an algorithm or scheme that produces insufficient entropy, leaving patterns or clusters of values that are more likely to occur than others.

How developers prevent this class of flaw

  • Determine the necessary entropy to adequately provide for randomness and predictability. This can be achieved by increasing the number of bits of objects such as keys and seeds.

More Insufficient Entropy vulnerabilities (CWE-331)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Insufficient Entropy vulnerabilities

Spotted an error? Tell us.