CyberSecBulletin
CVE-2026-54409NVD status: Analyzed

UniFi Protect Application: Improper Initialization

CVE-2026-54409 is a high-severity improper initialization vulnerability in UniFi Protect Application from Ubiquiti, with a CVSS 3.1 base score of 8.1 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 7.1.83 as the first without the flaw, so updating UniFi Protect Application to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.44% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update UniFi Protect Application to 7.1.83 or a later version.
  2. Update Unifi Protect to 7.1.83 or a later version.
  3. Read the advisory on community.ui.com for workarounds and exact fixed builds.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
UbiquitiUniFi Protect Applicationbefore 7.1.837.1.83
UIUnifi Protectbefore 7.1.837.1.83

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
HighSuccess depends on conditions outside the attacker's control.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.

Scoring systemScoreSeverityScored by
CVSS 3.17.5HighCNA (hackerone.com)
CVSS 3.18.1HighNVD

Official description

A malicious actor with access to the network and under certain conditions could exploit an Improper Initialization vulnerability found in UniFi Protect Application to bypass authentication in UniFi Protect Cameras.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Initialization

The product does not initialize or incorrectly initializes a resource.

How developers prevent this class of flaw

  • Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, in Java, if the programmer does not explicitly initialize a variable, then the code could produce a compile-time error (if the variable is local) or automatically initialize the variable to the default value for the variable's type. In Perl, if explicit initialization is not performed, then a default value of undef is assigned, which is interpreted as 0, false, or an equivalent value depending on the context in which the variable is accessed.
  • Identify all variables and data stores that receive information from external sources, and apply input validation to make sure that they are only initialized to expected values.
  • Explicitly initialize all your variables and other data stores, either during declaration or just before the first usage.

More Improper Initialization vulnerabilities (CWE-665)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in UniFi Protect Application

All UniFi Protect Application vulnerabilities

Recent Improper Initialization vulnerabilities

Spotted an error? Tell us.