CyberSecBulletin
CVE-2026-61411NVD status: Analyzed

Container Storage Modules: Insertion of Sensitive Information into Log File

CVE-2026-61411 is a high-severity insertion of sensitive information into log file vulnerability in Container Storage Modules from Dell, with a CVSS 3.1 base score of 7.7 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists version 1.18.0 or later as the first without the flaw, so updating Container Storage Modules to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.23% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Container Storage Modules to 1.18.0 or later or a later version.
  2. Read the advisory on dell.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
DellContainer Storage Modulesbefore 1.18.0 or later1.18.0 or later

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
NoneNothing can be modified.
Availability
NoneAvailability is not affected.

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N. Scored by CNA (emc.com).

Official description

Dell Container Storage Modules, versions prior to 1.18.0, contain(s) an Insertion of Sensitive Information into Log File vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Information disclosure.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Insertion of Sensitive Information into Log File

The product writes sensitive information to a log file.

How developers prevent this class of flaw

  • Consider seriously the sensitivity of the information written into log files. Do not write secrets into the log files.
  • Remove debug log files before deploying the application into production.
  • Protect log files against unauthorized read/write.

More Insertion of Sensitive Information into Log File vulnerabilities (CWE-532)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in Container Storage Modules

All Container Storage Modules vulnerabilities

Recent Insertion of Sensitive Information into Log File vulnerabilities

Spotted an error? Tell us.