CyberSecBulletin
CVE-2026-63353NVD status: Awaiting Analysis

SIMATIC Drive Controller CPU 1504D TF: Improper Neutralization of Input During Web Page Generation

CVE-2026-63353 is a critical-severity improper neutralization of input during web page generation vulnerability in SIMATIC Drive Controller CPU 1504D TF from Siemens, with a CVSS 3.1 base score of 9.6 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected SIMATIC Drive Controller CPU 1504D TF versions: all versions. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.31% chance of exploitation within 30 days, which is low compared with other CVEs.

Patch this week

Critical severity: a successful attack would have severe impact.

What to do

  1. Check which version of SIMATIC Drive Controller CPU 1504D TF you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
SiemensSIMATIC Drive Controller CPU 1504D TFall versionsNot stated
SiemensSIMATIC Drive Controller CPU 1507D TFall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1510SP F-1 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1510SP-1 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1512SP F-1 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1512SP-1 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1514SP F-2 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1514SP-2 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1514SPT F-2 PNall versionsNot stated
SiemensSIMATIC ET 200SP CPU 1514SPT-2 PNall versionsNot stated
SiemensSIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants)all versionsNot stated
SiemensSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V2 CPUs - Windows OSall versionsNot stated
SiemensSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Industrial OSall versionsNot stated
SiemensSIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) V3 CPUs - Windows OSall versionsNot stated
SiemensSIMATIC ET 200SP Open Controller CPU 1515SP PC3 V4 CPUsall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1511-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1511C-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1511F-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1511T-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1511TF-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1512C-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1513-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1513F-1 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1513pro F-2 PNall versionsNot stated
SiemensSIMATIC S7-1500 CPU 1513pro-2 PNall versionsNot stated

Version data comes from the organisation that assigned the CVE; 35 further products are omitted here. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
ChangedThe attack can reach beyond the vulnerable component into other systems.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H. Scored by CNA (siemens.com).

Scoring systemScoreSeverityScored by
CVSS 4.09.4CriticalCNA (siemens.com)
CVSS 3.19.6CriticalCNA (siemens.com)

Official description

Affected devices do not properly sanitize comment fields contained in imported trace files before rendering them on the Trace page. This could allow an attacker to social engineer an authorized user who holds the function right “Read diagnostics” into importing a specially crafted trace file. Successful exploitation could allow attacker-controlled JavaScript to execute in the user’s browser session and perform PLC operations through the web server within the scope of the user’s authorization.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Input During Web Page Generation

The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.

How developers prevent this class of flaw

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. Examples of libraries and frameworks that make it easier to generate properly encoded output include Microsoft's Anti-XSS library, the OWASP ESAPI Encoding module, and Apache Wicket.
  • Understand all the potential areas where untrusted inputs can enter your software: parameters or arguments, cookies, anything read from the network, environment variables, reverse DNS lookups, query results, request headers, URL components, e-mail, files, filenames, databases, and any external systems that provide data to the application. Remember that such inputs may be obtained indirectly through API calls.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Input During Web Page Generation vulnerabilities (CWE-79)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in SIMATIC Drive Controller CPU 1504D TF

All SIMATIC Drive Controller CPU 1504D TF vulnerabilities

Recent Improper Neutralization of Input During Web Page Generation vulnerabilities

Spotted an error? Tell us.