CyberSecBulletin
CVE-2026-73669NVD status: Awaiting Analysis

Philips Hue Bridge Pro: Missing Authentication for Critical Functionality

CVE-2026-73669 is a high-severity missing authentication for critical functionality vulnerability in Philips Hue Bridge Pro from Signify, with a CVSS 3.1 base score of 7.3 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 1.77.2071318010 as the first without the flaw, so updating Philips Hue Bridge Pro to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.52% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update Philips Hue Bridge Pro to 1.77.2071318010 or a later version.
  2. Read the advisory on philips-hue.com for workarounds and exact fixed builds.
  3. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
SignifyPhilips Hue Bridge Probefore 1.77.20713180101.77.2071318010

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
LowSome restricted data can be read.
Integrity
LowLimited modification of data is possible.
Availability
LowPerformance or availability is reduced.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L. Scored by CNA.

Scoring systemScoreSeverityScored by
CVSS 4.06.9MediumCNA
CVSS 3.17.3HighCNA

Official description

The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker service that listens on all network interfaces without authentication. An unauthenticated attacker with network access to the MQTT service on a vulnerable system can read data and control connected lights. Fixed in 1.77.2071318010.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Missing Authentication for Critical Functionality

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

How developers prevent this class of flaw

  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator.
  • When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data.

More Missing Authentication for Critical Functionality vulnerabilities (CWE-306)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Missing Authentication for Critical Functionality vulnerabilities

Spotted an error? Tell us.