CyberSecBulletin
CVE-2026-76461Exploited in the wildNVD status: Analyzed

Cisco Secure Email Gateway SQL Injection

CVE-2026-76461 is a critical-severity improper neutralization of special elements used in an SQL command vulnerability in Cisco Secure Email from Cisco, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected Cisco Secure Email versions: 14.0.0-698; 13.5.1-277; 13.0.0-392, and others listed below. The record does not name a fixed version, so check the vendor advisory. CISA added it to the Known Exploited Vulnerabilities catalogue on September 14, 2026, which means attacks have been observed in the wild.

Patch now

Attackers are already exploiting this vulnerability, according to CISA.

What to do

  1. Update Asyncos to 15.5.5-014 or 16.0.4-302 or 16.5.0-780, whichever matches your release line, or a later version.
  2. CISA's required action: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
  3. Read the advisory on sec.cloudapps.cisco.com for workarounds and exact fixed builds.
  4. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.

Affected products and versions

VendorProductAffected versionsFixed in
CiscoCisco Secure Email14.0.0-698; 13.5.1-277; 13.0.0-392; 14.2.0-620; 13.0.5-007; 13.5.4-038; 14.2.1-020; 14.3.0-032; and 15 more rangesNot stated
CiscoAsyncosbefore 15.5.5-014; 16.0 up to, but not including, 16.0.4-302; 16.5 up to, but not including, 16.5.0-78015.5.5-014, 16.0.4-302, 16.5.0-780

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (cisco.com).

Official description

A vulnerability in the email parsing of Cisco AsyncOS Software for Cisco Secure Email Gateway could allow an unauthenticated, remote attacker to execute arbitrary commands with root privileges on the underlying operating system. This vulnerability is due to insufficient validation in the email parsing logic. An attacker could exploit this vulnerability by sending a crafted email message that contains malicious SQL statements through an affected device. A successful exploit could allow the attacker to execute arbitrary SQL statements, leading to command execution with root privileges on the underlying operating system.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an SQL Command

The product constructs all or part of an SQL command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended SQL command when it is sent to a downstream component. Without sufficient removal or quoting of SQL syntax in user-controllable inputs, the generated SQL query can cause those inputs to be interpreted as SQL instead of ordinary user data.

How developers prevent this class of flaw

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using persistence layers such as Hibernate or Enterprise Java Beans, which can provide significant protection against SQL injection if used properly.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
  • When the set of acceptable objects, such as filenames or URLs, is limited or known, create a mapping from a set of fixed input values (such as numeric IDs) to the actual filenames or URLs, and reject all other inputs.

More Improper Neutralization of Special Elements used in an SQL Command vulnerabilities (CWE-89)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: active, automatable: yes, technical impact: total).
  3. Added to CISA's Known Exploited Vulnerabilities catalogue.
  4. Record last changed materially (score, affected products, status or references).
  5. Deadline for US federal agencies to remediate, set by CISA.

References

Third-party and government advisories

Our coverage

Other vulnerabilities in Cisco Secure Email

All Cisco Secure Email vulnerabilities

Recent Improper Neutralization of Special Elements used in an SQL Command vulnerabilities

Spotted an error? Tell us.