Tor: Incorrect Synchronization
CVE-2026-77584 is a high-severity incorrect synchronization vulnerability in Tor from Torproject, with a CVSS 3.1 base score of 8.2 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists version 0.4.9.10 as the first without the flaw, so updating Tor to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.25% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Tor to 0.4.9.10 or a later version.
- Read the advisory on gitlab.torproject.org for workarounds and exact fixed builds.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Torproject | Tor | 0.4.8.1-alpha up to, but not including, 0.4.9.10 | 0.4.9.10 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- NoneNo data is disclosed.
- Integrity
- HighData or code can be modified at will.
- Availability
- LowPerformance or availability is reduced.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 7.0 | High | CNA (mitre.org) |
| CVSS 3.1 | 8.2 | High | NVD |
Official description
Tor before 0.4.9.10 did not reject a CONFLUX_LINK cell that arrives on a circuit which already has attached streams. A malicious client could send a RELAY_COMMAND_BEGIN before the CONFLUX_LINK on the same circuit, attaching an exit stream that would later end up orphan leaving a dangling circuit back-pointer and a use-after-free (UAF) when the circuit is freed. This is TROVE-2026-025.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Incorrect Synchronization
The product utilizes a shared resource in a concurrent manner, but it does not correctly synchronize access to the resource.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Other vulnerabilities in Tor
- 9.3 Critical severity
- 8.2 High severity
- 9.0 Critical severity
- 7.5 High severity
- 7.5 High severity
- 7.5 High severity
Recent Incorrect Synchronization vulnerabilities
- 9.1 Critical severity
- 7.5 High severity