CyberSecBulletin
CVE-2026-78685NVD status: Deferred

Medical Practice Management System: Improper Verification of Source of a Communication Channel

CVE-2026-78685 is a high-severity improper verification of source of a communication channel vulnerability in Medical Practice Management System from Le-yan, with a CVSS 3.1 base score of 8.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, but only if a user takes part, for example by opening a link or file. Affected Medical Practice Management System versions: 2.4.2.8 through 2.5.1.9. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.64% chance of exploitation within 30 days, higher than 51% of scored CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Check which version of Medical Practice Management System you run against the affected versions below, and install the vendor's latest release.
  2. Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
  3. Because the attack needs a user to take part, warn users about unexpected links and files related to this product until it is patched.

Affected products and versions

VendorProductAffected versionsFixed in
Le-yanMedical Practice Management System2.4.2.8 through 2.5.1.9Not stated

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
NetworkCan be exploited remotely over a network, including the internet.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
NoneNo account or login is needed.
User interaction
RequiredA user must take an action such as opening a file or link.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H. Scored by CNA (cert.org.tw).

Scoring systemScoreSeverityScored by
CVSS 4.08.6HighCNA (cert.org.tw)
CVSS 3.18.8HighCNA (cert.org.tw)

Official description

Medical Practice Management System developed by Le-yan has a Remote Code Execution vulnerability. Unauthenticated remote attackers can execute arbitrary OS commamnds via a crafted HTML page.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Verification of Source of a Communication Channel

The product establishes a communication channel to handle an incoming request that has been initiated by an actor, but it does not properly verify that the request is coming from the expected origin.

How developers prevent this class of flaw

  • Use a mechanism that can validate the identity of the source, such as a certificate, and validate the integrity of data to ensure that it cannot be modified in transit using an Adversary-in-the-Middle (AITM) attack. When designing functionality of actions in the URL scheme, consider whether the action should be accessible to all mobile applications, or if an allowlist of applications to interface with is appropriate.

More Improper Verification of Source of a Communication Channel vulnerabilities (CWE-940)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Recent Improper Verification of Source of a Communication Channel vulnerabilities

Spotted an error? Tell us.