ash_graphql: Incorrect Authorization
CVE-2026-80223 is a high-severity incorrect authorization vulnerability in ash_graphql from Ash-project, with a CVSS 4.0 base score of 7.1 out of 10. It can be exploited remotely over the network by an attacker with a low-privileged account, without any action from a user. The record lists versions 1.11.0, 6e30b8b5a04bdeaed5d7514caa6b2d056d8d993e as the first without the flaw, so updating ash_graphql to one of those releases or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.43% chance of exploitation within 30 days, which is low compared with other CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update ash_graphql to 1.11.0 or 6e30b8b5a04bdeaed5d7514caa6b2d056d8d993e, whichever matches your release line, or a later version.
- Read the advisory on github.com for workarounds and exact fixed builds.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Ash-project | ash_graphql | 1.4.0 up to, but not including, 1.11.0; 4c377e541a2adb6befc651f3dccc6a797bc58ba9 up to, but not including, 6e30b8b5a04bdeaed5d7514caa6b2d056d8d993e | 1.11.0, 6e30b8b5a04bdeaed5d7514caa6b2d056d8d993e |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Attack requirements
- NoneThe attack does not depend on a particular deployment or configuration.
- Privileges required
- LowA basic user account is enough.
- User interaction
- NoneNo action by a victim is required.
- Confidentiality (vulnerable system)
- HighSerious loss of confidentiality on the vulnerable system.
- Integrity (vulnerable system)
- NoneNo loss of integrity on the vulnerable system.
- Availability (vulnerable system)
- NoneNo loss of availability on the vulnerable system.
- Confidentiality (other systems)
- NoneNo loss of confidentiality on systems beyond the vulnerable one.
- Integrity (other systems)
- NoneNo loss of integrity on systems beyond the vulnerable one.
- Availability (other systems)
- NoneNo loss of availability on systems beyond the vulnerable one.
Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA.
Official description
Incorrect Authorization vulnerability in ash-project ash_graphql allows an authenticated subscriber in one tenant to receive another tenant's records over GraphQL subscriptions. The subscription resolver in AshGraphql.Graphql.Resolver authorizes each notification payload in memory: its fast path calls Ash.can/3 with run_queries?: false, which evaluates the read policy filter against the in-memory record via Ash.Expr.eval/2 and never issues a query. Ash applies multitenancy at query-build and data-layer-prefix time, not inside query.filter, so the evaluated policy carries no tenant condition and a tenant-B notification routed to a tenant-A subscriber is emitted whenever the policy filter is true. The single-notification clause has no tenant guard at all, and the batched clause checks only the head of the notification list, so non-head entries authorize purely in memory. A tenant-scoped read is reached only when filter evaluation fails. This issue affects ash_graphql: from 1.4.0 before 1.11.0.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Incorrect Authorization
The product performs an authorization check when an actor attempts to access a resource or perform an action, but it does not correctly perform the check.
How developers prevent this class of flaw
- Divide the product into anonymous, normal, privileged, and administrative areas. Reduce the attack surface by carefully mapping roles with data and functionality. Use role-based access control (RBAC) to enforce the roles at the appropriate boundaries. Note that this approach may not protect against horizontal authorization, i.e., it will not protect a user from attacking others with the same role.
- Ensure that access control checks are performed related to the business logic. These checks may be different than the access control checks that are applied to more generic resources such as files, connections, processes, memory, and database records. For example, a database may restrict access for medical records to a specific database user, but each record might only be intended to be accessible to the patient and the patient's doctor.
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid. For example, consider using authorization frameworks such as the JAAS Authorization Framework and the OWASP ESAPI Access Control feature.
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: poc, automatable: no, technical impact: partial).
- Record last changed materially (score, affected products, status or references).
References
Patches and release notes
Other vulnerabilities in ash_graphql
- 8.7 High severity
Recent Incorrect Authorization vulnerabilities
- 8.1 High severity
- 7.5 High severity
- 9.1 Critical severity
- 9.1 Critical severity
- 9.8 Critical severity
- 7.1 High severity
Spotted an error? Tell us.