Progress LoadMaster Command Injection
CVE-2026-8037 is a critical-severity improper neutralization of special elements used in a command vulnerability in LoadMaster from Progress Software, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. The record lists versions V7.2.63.2, V7.2.54.18 as the first without the flaw, so updating LoadMaster to one of those releases or later removes the exposure. CISA added it to the Known Exploited Vulnerabilities catalogue on August 7, 2026, which means attacks have been observed in the wild.
Attackers are already exploiting this vulnerability, according to CISA.
What to do
- Update LoadMaster to V7.2.63.2 or V7.2.54.18, whichever matches your release line, or a later version.
- Update ECS Connections Manager to V7.2.63.2 or a later version.
- Update Object Scale Connection Manager to V7.2.63.2 or a later version.
- CISA's required action: Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
- Read the advisory on community.progress.com for workarounds and exact fixed builds.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| Progress Software | LoadMaster | V7.2.60.0 up to, but not including, V7.2.63.2; V7.2.54.12 up to, but not including, V7.2.54.18 | V7.2.63.2, V7.2.54.18 |
| Progress Software | ECS Connections Manager | V7.2.60.0 up to, but not including, V7.2.63.2 | V7.2.63.2 |
| Progress Software | Object Scale Connection Manager | V7.2.60.0 up to, but not including, V7.2.63.2 | V7.2.63.2 |
| Progress Software | MOVEit WAF | V7.2.60.0 up to, but not including, V7.2.63.2 | V7.2.63.2 |
| Progress Software | Connection Manager For Objectscale | before 7.2.63.2 | 7.2.63.2 |
| Progress Software | Ecs Connection Manager | before 7.2.63.2 | 7.2.63.2 |
| Progress Software | Moveit Web Application Firewall | before 7.2.63.2 | 7.2.63.2 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by NVD.
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 3.1 | 9.6 | Critical | CNA (progress.com) |
| CVSS 3.1 | 9.8 | Critical | NVD |
Official description
OS Command Injection Remote Code Execution Vulnerability in API in Progress ADC Products allows an un-authenticated attacker to execute arbitrary commands on the LoadMaster appliance by exploiting unsanitized input in multiple command endpoints
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in a Command
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- If possible, ensure that all external commands called from the program are statically created.
- Run time: Run time policy enforcement may be used in an allowlist fashion to prevent use of any non-sanctioned commands.
More Improper Neutralization of Special Elements used in a Command vulnerabilities (CWE-77)
Timeline
- CVE record published.
- Added to CISA's Known Exploited Vulnerabilities catalogue.
- Deadline for US federal agencies to remediate, set by CISA.
- CISA published its SSVC assessment (exploitation: active, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Advisories
Patches and release notes
- labs.watchtowr.com/enterprise-tech-in-shell-out-progress-kemp-loadmaster-uninitialized-heap-to-pre-auth-rce-c…Exploit, Third Party Advisory
Third-party and government advisories
- cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2026-8037US Government Resource
Other vulnerabilities in LoadMaster
- 8.0 High severity
- 8.0 High severity
- 8.4 High severity
- 8.4 High severity
- 8.4 High severity
- 7.2 High severity
Recent Improper Neutralization of Special Elements used in a Command vulnerabilities
- 8.8 High severity
- 7.5 High severity
- 7.2 High severity
- 7.2 High severity
- 7.2 High severity
- 7.2 High severity
Spotted an error? Tell us.