HMT.CM2507 Firmware: Use of Password Hash With Insufficient Computational Effort
CVE-2026-85497 is a critical-severity use of password hash with insufficient computational effort vulnerability in HMT.CM2507 Firmware from CareCam, with a CVSS 3.1 base score of 9.8 out of 10. It can be exploited remotely over the network by an unauthenticated attacker, without any action from a user. Affected HMT.CM2507 Firmware versions: v251211.1507. The record does not name a fixed version, so check the vendor advisory. There is no confirmed exploitation so far. EPSS estimates a 0.34% chance of exploitation within 30 days, which is low compared with other CVEs.
Critical severity: a successful attack would have severe impact.
What to do
- Check which version of HMT.CM2507 Firmware you run against the affected versions below, and install the vendor's latest release.
- Until you can update, restrict network access to the affected service so it is not reachable from untrusted networks.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| CareCam | HMT.CM2507 Firmware | v251211.1507 | Not stated |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- NetworkCan be exploited remotely over a network, including the internet.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Scope
- UnchangedImpact stays within the vulnerable component.
- Confidentiality
- HighAll data handled by the component can be read.
- Integrity
- HighData or code can be modified at will.
- Availability
- HighThe component can be taken down completely.
Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (hq.dhs.gov).
| Scoring system | Score | Severity | Scored by |
|---|---|---|---|
| CVSS 4.0 | 9.3 | Critical | CNA (hq.dhs.gov) |
| CVSS 3.1 | 9.8 | Critical | CNA (hq.dhs.gov) |
Official description
CareCam CM2507 IP cameras store the device's root-account password using a fixed legacy password hash that provides insufficient resistance to offline cracking. An attacker who obtains the firmware image or password database could recover the associated credential, which may also be reusable across other devices running the same firmware.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Use of Password Hash With Insufficient Computational Effort
The product generates a hash for a password, but it uses a scheme that does not provide a sufficient level of computational effort that would make password cracking attacks infeasible or expensive.
How developers prevent this class of flaw
- When using industry-approved techniques, use them correctly. Don't cut corners by skipping resource-intensive steps (CWE-325). These steps are often essential for preventing common attacks.
More Use of Password Hash With Insufficient Computational Effort vulnerabilities (CWE-916)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: yes, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
Other vulnerabilities in HMT.CM2507 Firmware
- 9.8 Critical severity
- 7.5 High severity
- 7.5 High severity
Recent Use of Password Hash With Insufficient Computational Effort vulnerabilities
- 7.5 High severity
- 7.5 High severity
- 8.7 High severity
- 9.8 Critical severity
- 9.8 Critical severity
- 7.8 High severity
Spotted an error? Tell us.