CyberSecBulletin
CVE-2026-88886NVD status: Awaiting Analysis

renovate: Improper Neutralization of Special Elements used in an OS Command

CVE-2026-88886 is a high-severity improper neutralization of special elements used in an OS command vulnerability in renovate from Renovatebot, with a CVSS 3.1 base score of 7.8 out of 10. It can be exploited with local access to the system by an attacker with a low-privileged account, without any action from a user. The record lists version 44.14.7 as the first without the flaw, so updating renovate to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 0.23% chance of exploitation within 30 days, which is low compared with other CVEs.

Next patch cycle

High severity with no evidence of exploitation so far.

What to do

  1. Update renovate to 44.14.7 or a later version.
  2. Update renovate-ce to 15.4.0 or a later version.
  3. Update renovate-ee-server to 15.4.0 or a later version.
  4. Read the advisory on github.com for workarounds and exact fixed builds.

Affected products and versions

VendorProductAffected versionsFixed in
Renovatebotrenovatebefore 44.14.744.14.7
Mendrenovate-cebefore 15.4.015.4.0
Mendrenovate-ee-serverbefore 15.4.015.4.0
Mendrenovate-ee-workerbefore 15.4.015.4.0
Mendmend-renovate-cebefore 15.4.015.4.0
Mendmend-renovate-enterprise-editionbefore 10.4.010.4.0

Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.

How the severity score breaks down

Attack vector
LocalThe attacker needs local access or must trick a user into running something.
Attack complexity
LowNo special conditions are needed; the attack works reliably.
Privileges required
LowA basic user account is enough.
User interaction
NoneNo action by a victim is required.
Scope
UnchangedImpact stays within the vulnerable component.
Confidentiality
HighAll data handled by the component can be read.
Integrity
HighData or code can be modified at will.
Availability
HighThe component can be taken down completely.

Vector: CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H. Scored by CNA (vulncheck.com).

Scoring systemScoreSeverityScored by
CVSS 4.08.5HighCNA (vulncheck.com)
CVSS 3.17.8HighCNA (vulncheck.com)

Official description

Renovate is a dependency update automation tool. In versions before 44.14.7 (and in Mend Renovate CE/EE distributions before 15.4.0, and the mend-renovate-enterprise-edition Helm chart before 10.4.0), the manager/gradle-wrapper module does not escape the distributionUrl value read from a repository's gradle/wrapper/gradle-wrapper.properties file before invoking the Gradle Wrapper CLI. In self-hosted deployments configured with binarySource=docker and allowedUnsafeExecutions=['gradleWrapper', ...], a repository that supplies a crafted distributionUrl (for example, appending a shell metacharacter and command) can cause arbitrary commands to be executed as the Renovate user when Renovate processes a Gradle Wrapper update. The issue is fixed in Renovate 44.14.7; as a workaround, remove 'gradleWrapper' from allowedUnsafeExecutions.

Source: the CVE record as published by its numbering authority, via NVD and CVE.org.

The underlying weakness: Improper Neutralization of Special Elements used in an OS Command

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.

How developers prevent this class of flaw

  • If at all possible, use library calls rather than external processes to recreate the desired functionality.
  • For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.

More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)

Timeline

  1. CVE record published.
  2. CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
  3. Record last changed materially (score, affected products, status or references).

References

Other vulnerabilities in renovate

All renovate vulnerabilities

Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities

Spotted an error? Tell us.