Archer BE800 V1: Improper Neutralization of Special Elements used in an OS Command
CVE-2026-9254 is a high-severity improper neutralization of special elements used in an OS command vulnerability in Archer BE800 V1 from TP-Link, with a CVSS 4.0 base score of 8.7 out of 10. It can be exploited from the same local network by an unauthenticated attacker, without any action from a user. The record lists version 1.4.2 Build 260708 as the first without the flaw, so updating Archer BE800 V1 to that release or later removes the exposure. There is no confirmed exploitation so far. EPSS estimates a 3.06% chance of exploitation within 30 days, higher than 88% of scored CVEs.
High severity with no evidence of exploitation so far.
What to do
- Update Archer BE800 V1 to 1.4.2 Build 260708 or a later version.
- Update Archer BE3600 V1 to 1.2.6 Build 20260617 or a later version.
- Update Archer AX75 V1 to 1.1.6 Build 260716 or a later version.
Affected products and versions
| Vendor | Product | Affected versions | Fixed in |
|---|---|---|---|
| TP-Link | Archer BE800 V1 | before 1.4.2 Build 260708 | 1.4.2 Build 260708 |
| TP-Link | Archer BE3600 V1 | before 1.2.6 Build 20260617 | 1.2.6 Build 20260617 |
| TP-Link | Archer AX75 V1 | before 1.1.6 Build 260716 | 1.1.6 Build 260716 |
Version data comes from the organisation that assigned the CVE. Confirm against the vendor advisory before deciding you are unaffected.
How the severity score breaks down
- Attack vector
- AdjacentThe attacker must be on the same local network segment.
- Attack complexity
- LowNo special conditions are needed; the attack works reliably.
- Attack requirements
- NoneThe attack does not depend on a particular deployment or configuration.
- Privileges required
- NoneNo account or login is needed.
- User interaction
- NoneNo action by a victim is required.
- Confidentiality (vulnerable system)
- HighSerious loss of confidentiality on the vulnerable system.
- Integrity (vulnerable system)
- HighSerious loss of integrity on the vulnerable system.
- Availability (vulnerable system)
- HighSerious loss of availability on the vulnerable system.
- Confidentiality (other systems)
- LowLimited loss of confidentiality on systems beyond the vulnerable one.
- Integrity (other systems)
- LowLimited loss of integrity on systems beyond the vulnerable one.
- Availability (other systems)
- LowLimited loss of availability on systems beyond the vulnerable one.
Vector: CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X. Scored by CNA.
Official description
An unauthenticated OS command injection vulnerability exists in the parental control functionality of Archer BE800 V1, BE3600 V1, and AX75 V1 due to improper filtering and neutralization of special characters in certain parameters. A LAN-based attacker can inject arbitrary commands and execute them with root privileges. Successful exploitation may result in complete device compromise and impact the confidentiality, integrity, and availability of the affected device and network traffic.
Source: the CVE record as published by its numbering authority, via NVD and CVE.org.
The underlying weakness: Improper Neutralization of Special Elements used in an OS Command
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command before it is sent to a downstream component.
How developers prevent this class of flaw
- If at all possible, use library calls rather than external processes to recreate the desired functionality.
- For any data that will be used to generate a command to be executed, keep as much of that data out of external control as possible. For example, in web applications, this may require storing the data locally in the session's state instead of sending it out to the client in a hidden form field.
- For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
More Improper Neutralization of Special Elements used in an OS Command vulnerabilities (CWE-78)
Timeline
- CVE record published.
- CISA published its SSVC assessment (exploitation: none, automatable: no, technical impact: total).
- Record last changed materially (score, affected products, status or references).
References
Other references
- tp-link.com/en/support/download/archer-ax75/v1/#Firmware
- tp-link.com/en/support/download/archer-be3600/v1/#Firmware
- tp-link.com/en/support/download/archer-be800/v1/#Firmware
- tp-link.com/kr/support/download/archer-be3600/v1/#Firmware
- tp-link.com/us/support/download/archer-ax75/v1/#Firmware
- tp-link.com/us/support/download/archer-be3600/v1/#Firmware
- tp-link.com/us/support/download/archer-be800/v1/#Firmware
- tp-link.com/us/support/faq/5264/
Other vulnerabilities in Archer BE800 V1
- 8.5 High severity
Recent Improper Neutralization of Special Elements used in an OS Command vulnerabilities
- 8.5 High severity
- 7.2 High severity
- 7.2 High severity
- 7.2 High severity
- 7.2 High severity
- 7.2 High severity
Spotted an error? Tell us.