PRA-ES8P2S vulnerabilities
3 known vulnerabilities in PRA-ES8P2S from Bosch. 3 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 8.8 High severity
PRA-ES8P2S: Improper Privilege Management
The user access rights validation in the web server of the Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 was insufficient. This would allow a non-administrator user to obtain administrator user access rights.
- 9.8 Critical severity
PRA-ES8P2S: Improper Privilege Management
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 runs its web server with root privilege. In combination with CVE-2022-23534 this could give an attacker root access to the switch.
- 9.8 Critical severity
PRA-ES8P2S: Improper Neutralization of Special Elements used in an OS Command
The Bosch Ethernet switch PRA-ES8P2S with software version 1.01.05 and earlier was found to be vulnerable to command injection through its diagnostics web interface. This allows execution of shell commands.