Clininet vulnerabilities
2 known vulnerabilities in Clininet from CGM. 2 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
2vulnerabilities
0critical
2high
0exploited
7.7average CVSS score
Latest first
- 7.5 High severity
CGM CLININET: Authorization Bypass Through User-Controlled Key
The CGM CLININET application uses direct, sequential object identifiers "MessageID" without proper authorization checks. By modifying the parameter in the GET request, an attacker can access messages and attachments belonging to other users.
- 7.8 High severity
CGM CLININET: Use of Client-Side Authentication
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone