- 9.8 Critical severity
Lantronix EDS5000 Code Injection Exploited
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The HTTP RPC module executes a shell command to write logs when user's authentication fails. The username is directly concatenated with the command without any sanitization. This allow attackers to inject
- 7.2 High severity
EDS5000 series: Improper Neutralization of Special Elements used in an OS Command
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "tunnel" parameter when killing a tunnel connection. Injected commands are executed with root privileges.
- 7.2 High severity
EDS5000 series: Improper Neutralization of Special Elements used in an OS Command
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. The Log Info page allows users to see log files by specifying their names. Due to a missing sanitization in the file name parameter, an authenticated attacker can inject arbitrary OS commands that are exe
- 7.2 High severity
EDS5000 series: Improper Neutralization of Special Elements used in an OS Command
An issue was discovered in Lantronix EDS5000 2.1.0.0R3. An authenticated attacker can inject OS commands into the "name" parameter when deleting SSL credentials through the management interface. Injected commands are executed with root privileges.