e-Clinic Healthcare System ECHS vulnerabilities
1 known vulnerability in e-Clinic Healthcare System ECHS from PicoTronica. 1 is rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
1vulnerabilities
0critical
1high
0exploited
7.3average CVSS score
Latest first
- 7.3 High severity
e-Clinic Healthcare System ECHS: Use of Hard-coded Password
A flaw has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. The impacted element is an unknown function of the file /cdemos/echs/priv/echs.js. This manipulation of the argument ADMIN_KEY causes hard-coded credentials. The attack is possible to be