mso5000 vulnerabilities
2 known vulnerabilities in mso5000 from Rigol. 2 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
2vulnerabilities
1critical
1high
0exploited
8.7average CVSS score
Latest first
- 7.5 High severity
mso5000: Missing Authentication for Critical Functionality
The web interface on the RIGOL MSO5000 digital oscilloscope with firmware 00.01.03.00.03 allows remote attackers to change the admin password via a zero-length pass0 to the webcontrol changepwd.cgi application, i.e., the entered password only needs to match th
- 9.8 Critical severity
mso5000: Improper Neutralization of Special Elements used in an OS Command
The web interface on the RIGOL MSO5000 digital oscilloscope with firmware 00.01.03.00.03 allows remote attackers to execute arbitrary code via shell metacharacters in pass1 to the webcontrol changepwd.cgi application.