Field Analytics vulnerabilities
4 known vulnerabilities in Field Analytics from SICK. 4 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 7.5 High severity
SICK Field Analytics: Exposure of Sensitive Information to an Unauthorized Actor
The created backup files are unencrypted, making the application vulnerable for gathering sensitive information by downloading and decompressing the backup files.
- 9.8 Critical severity
SICK Field Analytics: Insufficient Verification of Data Authenticity
The backup ZIPs are not signed by the application, leading to the possibility that an attacker can download a backup ZIP, modify and re-upload it. This allows the attacker to disrupt the application by configuring the services in a way that they are unable to
- 9.1 Critical severity
SICK Field Analytics: Use of a Broken or Risky Cryptographic Algorithm
A service supports the use of a deprecated and unsafe TLS version. This could be exploited to expose sensitive information, modify data in unexpected ways or spoof identities of other users or devices, affecting the confidentiality and integrity of the device.
- 7.5 High severity
Field Analytics: Exposure of Sensitive Information to an Unauthorized Actor
A remote unauthorized attacker may gather sensitive information of the application, due to missing authorization of configuration settings of the product.