inspector61x_firmware vulnerabilities
5 known vulnerabilities in inspector61x_firmware from SICK. 5 are rated high or critical. Each entry lists the affected versions and the release that fixes it, where the vendor has published one.
Latest first
- 8.2 High severity
SICK InspectorP61x: Missing Authentication for Critical Functionality
Lua apps can be deployed, removed, started, reloaded or stopped without authorization via AppManager. This allows an attacker to remove legitimate apps creating a DoS attack, read and write files or load apps that use all features of the product available to a
- 7.3 High severity
SICK InspectorP61x: Missing Authentication for Critical Functionality
Unauthenticated CROWN APIs allow access to critical functions. This leads to the accessibility of large parts of the web application without authentication.
- 9.0 Critical severity
SICK InspectorP61x: Hidden Functionality
The product is vulnerable to pass-the-hash attacks in combination with hardcoded credentials of hidden user levels. This means that an attacker can log in with the hidden user levels and gain full access to the device.
- 8.8 High severity
SICK InspectorP61x: Reliance on Obfuscation or Encryption of Security-Relevant Inputs without Integrity Checking
Since the firmware update is not validated, an attacker can install modified firmware on the device. This has a high impact on the availabilty, integrity and confidentiality up to the complete compromise of the device.
- 8.8 High severity
SICK InspectorP61x: Improper Control of Generation of Code
Due to missing input validation during one step of the firmware update process, the product is vulnerable to remote code execution. With network access and the user level ”Service”, an attacker can execute arbitrary system commands in the root user’s contexts.